  1. Digital Coating Thickness Gauge Accu-456

    Range: 0-1500m /0-60mil Resolution: 0.1m/mil Accuracy: (1+2%m) Test Limits: Surface curvature: convex 5 mm / concave 5 mm Minimum test surface: 10mm Minimum thickness of base material: 0.4mm Operation Condition Temperature: -1050 Humidity: 10%RH-85RH Product Size 126 x 69 x 35mm Weight 97g (batteries NOT included)
    Send Inquiry
  2. Paint Thickness Gauge ACCU-356A

    Measuring Continuous and Single Measurement available Memory 600 data store Unit Metric/Imperial switchable (mil/um selectable) Backlight Brightness adjustable, clear and easy reading under any light condition Alarm Set higher and lower alarm range for measuring Calibration Zero-in, 2 points calibration and multi-point calibration selectable Battery Low battery indication Data Transfer USB, Bluetooth Range 0-1500m /0-60mil Resolution 0.1m/mil Accuracy (1+2%m) Test Limits Surface curvature: convex 5 mm / concave 5 mm Minimum test surface: 10mm Minimum thickness of base material: 0.4mm Operation Condition(not in high magnetic field) Temperature: -1050 Humidity: 10%RH-85RH
    Send Inquiry
  3. DFT-222 Coating Thickness Gauge

    Measuring principle : Magnetic induction(F); Eddy Currents (NF) Measuring Range : 0 to 2000m (0 to 78.7mils) Accuracy : (2.5%+1m) (2.5%+0.039mils) Resolution : 0m~99.9m (0. lm) 100m~999m(1m)>1000m(0.01mm) Calibration : One point to four-point calibration, zero-point calibration Units : m, mm, mils Alarm : User can set the high/low alarm limit. Alarm icon displayed on LCD when over the limit Minimum curvature radius convex : 5mm Minimum curvature radius concave : 25mm Minimum measuring area : Diameter 20mm
    Send Inquiry
  4. Digital Coating Thickness Gauge DFT-111

    Measuring principle : Magnetic induction(F) ; Eddy Currents(NF) Measuring Range F : 0 to 5000m (0 to 196.8mils) Measuring Range N : 0 to 3000m (0 to 118.1mils) Accuracy : (2.5%+1m) (2.5%+0.039mils) Resolution : 0m~99.9m (0. lm) 100m~999m(1m)>1000m(0.01mm) Calibration : One point to four-point calibration, zero-point calibration Statistics : No. of readings, mean, minimum, maximum and standard deviation Units : m , mm, mils Alarm : User can set the high/low alarm limit. Alarm icon displayed on LCD when over the limit Minimum curvature radius convex : 5mm Minimum curvature radius concave : 25mm Minimum measuring area : Diameter 20mm Minimum thickness of substrate : 0.2mm (F) ; 0.2mm (NF)